Abstract
Numerical and experimental investigations on two-phase evaporative cooling performance for a moving electronic unit with high heat flux have been performed in a coiled channel heat exchanger. Based on the VOF model, the phase distribution of a 3D coiled channel was investigated. It was found that the main vapor streamline flowed through the inner side of one bend channel to the next one, which increased the contact frequency of the vapor and the liquid, improving the cooling performance. Moreover, the results were also verified by the experiment. The cooling effect was directly affected by heat concentration in the bend channel. An optimized method was implemented for this phenomenon. Decreasing the effective flow area and increasing the local velocity could establish a new force balance for the vapor and liquid, eliminating the heat concentration and improving the overall cooling performance.
| Original language | English |
|---|---|
| Pages (from-to) | 256-265 |
| Number of pages | 10 |
| Journal | Applied Thermal Engineering |
| Volume | 94 |
| DOIs | |
| State | Published - 5 Feb 2016 |
Keywords
- Coiled channel
- Cooling performance
- Electronic evaporative cooling
- Numerical simulation
- Phase distribution
- VOF
Fingerprint