Skip to main navigation Skip to search Skip to main content

Numerical and experimental analysis of two phase flow in ejector

  • Xi'an Jiaotong University

Research output: Contribution to journal › Conference article › peer-review

7 Scopus citations

Abstract

When the ejector was applied in the natural gas exploitation and sea water desalination industries, the ejector always operated on the two phase operation, because of the primary fluid or the induced fluid usually companying some water inside. The water inside the primary and induced gas will affect the ejector performance. In the present study, the experimental and CFD methods were used to investigate the two phase flow inside the ejector, when the water was injected into the induced flow. The results show that: when the water was injected into the induced flow, the experimental results decreased, as well as numerical results. The numerical results agreed with the experimental data, with the maximum deviations less than 20% for critical mode and less than 40% for sub-critical mode.

Original languageEnglish
Pages (from-to)1298-1301
Number of pages4
JournalEnergy Procedia
Volume61
DOIs
StatePublished - 2014
Event6th International Conference on Applied Energy, ICAE 2014 - Taipei, Taiwan, Province of China
Duration: 30 May 2014 → 2 Jun 2014

Keywords

  • Back pressure
  • Ejector
  • Entrainment ratio
  • Two phase flow

Fingerprint

Dive into the research topics of 'Numerical and experimental analysis of two phase flow in ejector'. Together they form a unique fingerprint.

Cite this