Abstract

The present experiment is conducted to study the nonuniform heat transfer of single-phase water turbulent flow and two-phase steamwater flow in horizontal helical coils tubes. The inner and the outer diameter of the tube are 11mm and 15mm respectively, and the ratio of the diameter of the coil to that of the tube is 23.27. The experimental pressure ranges from 0.5 to 3.0MPa, mass flowrate from 200 to 2500 kg/m2s, heat flux from 230 to 500kW/m2, and the maximum exit steam quality 0.S6. Along both the tube axial direction and the periphery on the crosssection, the local heat transfer coefficients are not evenly distributed. The secondary flow has less contribution to the enhancement heat transfer of the coil with increasing Reynolds number to a high level. Taking the average coefficient at outlet section as that of the coil is not reasonable.

Original languageEnglish
Title of host publicationNuclear Engineering
PublisherAmerican Society of Mechanical Engineers (ASME)
Pages107-113
Number of pages7
ISBN (Electronic)9780791818329
DOIs
StatePublished - 1997
EventASME 1997 International Mechanical Engineering Congress and Exposition, IMECE 1997 - Nuclear Engineering - Dallas, United States
Duration: 16 Nov 199721 Nov 1997

Publication series

NameASME International Mechanical Engineering Congress and Exposition, Proceedings (IMECE)
Volume1997-Z

Conference

ConferenceASME 1997 International Mechanical Engineering Congress and Exposition, IMECE 1997 - Nuclear Engineering
Country/TerritoryUnited States
CityDallas
Period16/11/9721/11/97

Fingerprint

Dive into the research topics of 'NONUNIFORM HEAT TRANSFER IN HORIZONTAL HELICAL COILS TUBE STEAM GENERATORS'. Together they form a unique fingerprint.

Cite this