TY - JOUR
T1 - Non-uniformity of gas/liquid flow in a riser and impact of operation and pipe configuration on slugging characteristics
AU - Zou, Suifeng
AU - Yao, Tian
AU - Guo, Liejin
AU - Li, Wensheng
AU - Wu, Quanhong
AU - Zhou, Hongliang
AU - Xie, Chen
AU - Liu, Weizhi
AU - Kuang, Shicai
N1 - Publisher Copyright:
© 2018 Elsevier Inc.
PY - 2018/9
Y1 - 2018/9
N2 - A pipeline-riser system is a typical complex pipe configuration in which the non-uniformity of gas/liquid flow is observed to be significant under certain flow rates. This article interprets slugging flow, the most common flow regime in a pipeline-riser system, in the context of non-uniformity, which differs from the approaches used to characterise slugging cycles in previous studies. By comparing data collected by several transmitters positioned locally on the riser and comparing flow in a simple vertical pipe, both the temporal and spatial non-uniformity of the gas/liquid distribution in the riser is presented and interpreted; the relationship between them is also illustrated. The non-uniformity of the flow provides an effective means to quantitatively evaluate the severity of slugging in a pipeline-riser system under different operating conditions. In addition to flow uniformity, specific flow characteristics can be affected by operating conditions as well as pipe configuration. Several factors closely related to the design of experimental facilities and procedures are investigated by a case study of three experimental loops with different layouts and dimensions, and several general findings are summarised. The results may contribute to a better and more specific understanding of gas/liquid flow mechanisms in a pipeline-riser system in addition to serving as a means to evaluate the features of laboratory pipeline-riser systems and the applicability of laboratory results in industrial cases.
AB - A pipeline-riser system is a typical complex pipe configuration in which the non-uniformity of gas/liquid flow is observed to be significant under certain flow rates. This article interprets slugging flow, the most common flow regime in a pipeline-riser system, in the context of non-uniformity, which differs from the approaches used to characterise slugging cycles in previous studies. By comparing data collected by several transmitters positioned locally on the riser and comparing flow in a simple vertical pipe, both the temporal and spatial non-uniformity of the gas/liquid distribution in the riser is presented and interpreted; the relationship between them is also illustrated. The non-uniformity of the flow provides an effective means to quantitatively evaluate the severity of slugging in a pipeline-riser system under different operating conditions. In addition to flow uniformity, specific flow characteristics can be affected by operating conditions as well as pipe configuration. Several factors closely related to the design of experimental facilities and procedures are investigated by a case study of three experimental loops with different layouts and dimensions, and several general findings are summarised. The results may contribute to a better and more specific understanding of gas/liquid flow mechanisms in a pipeline-riser system in addition to serving as a means to evaluate the features of laboratory pipeline-riser systems and the applicability of laboratory results in industrial cases.
KW - Active flow control
KW - Differential pressure
KW - Flow boundary condition
KW - Pipe configuration
KW - Pipeline-riser system
KW - Temporal and spatial non-uniformity
UR - https://www.scopus.com/pages/publications/85044453280
U2 - 10.1016/j.expthermflusci.2018.03.021
DO - 10.1016/j.expthermflusci.2018.03.021
M3 - 文章
AN - SCOPUS:85044453280
SN - 0894-1777
VL - 96
SP - 329
EP - 346
JO - Experimental Thermal and Fluid Science
JF - Experimental Thermal and Fluid Science
ER -