Skip to main navigation Skip to search Skip to main content

Multi-Parametric Retinal Microvascular Functional Perfusion Imaging Based on Dynamic Fundus Fluorescence Angiography

  • Diya Wang
  • , Qiao Wang
  • , Qiang Su
  • , Shun Wang
  • , Zhijie Jian
  • , Jianpu Li
  • , Fang Ye
  • , Yanli Hou
  • , Mingxi Wan
  • Xi'an Jiaotong University
  • Capital Medical University
  • The First Affiliated Hospital of Xi’an Jiaotong University
  • Shanghai Aerospace Electronic Technology Institute
  • Sun Yat-Sen University

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

Retinal microvascular disease has caused serious visual impairment widely in the world, which can be hopefully prevented via early and precision microvascular hemodynamic diagnosis. Due to artifacts from choroidal microvessels and tiny movements, current fundus microvascular imaging techniques including fundus fluorescein angiography (FFA) precisely identify retinal microvascular microstructural damage and abnormal hemodynamic changes difficulty, especially in the early stage. Therefore, this study proposes an FFA-based multi-parametric retinal microvascular functional perfusion imaging (RM-FPI) scheme to assess the microstructural damage and quantify its hemodynamic distribution precisely. Herein, a spatiotemporal filter based on singular value decomposition combined with a lognormal fitting model was used to remove the above artifacts. Dynamic FFAs of patients (n = 7) were collected first. The retinal time fluorescence intensity curves were extracted and the corresponding perfusion parameters were estimated after decomposition filtering and model fitting. Compared with in vivo results without filtering and fitting, the signal-to-clutter ratio of retinal perfusion curves, average contrast, and resolution of RM-FPI were up to 7.32 ± 0.43 dB, 14.34 ± 0.24 dB, and 11.0 ± 2.0 μm, respectively. RM-FPI imaged retinal microvascular distribution and quantified its spatial hemodynamic changes, which further characterized the parabolic distribution of local blood flow within diameters ranging from 9 to 400 μm. Finally, RM-FPI was used to quantify, visualize, and diagnose the retinal hemodynamics of retinal vein occlusion from mild to severe. Therefore, this study provided a scheme for early and precision diagnosis of retinal microvascular disease, which might be beneficial in preventing its development.

Original languageEnglish
Pages (from-to)3123-3133
Number of pages11
JournalIEEE Transactions on Biomedical Engineering
Volume71
Issue number11
DOIs
StatePublished - 2024

Keywords

  • Retinal microvascular diseases
  • functional perfusion imaging
  • fundus fluorescein angiography
  • hemodynamics

Fingerprint

Dive into the research topics of 'Multi-Parametric Retinal Microvascular Functional Perfusion Imaging Based on Dynamic Fundus Fluorescence Angiography'. Together they form a unique fingerprint.

Cite this