TY - GEN
T1 - Multi-energy CT image restoration algorithm based on the flat-panel X-ray source
AU - Li, Yang
AU - Duan, Jiayu
AU - Zhi, Shaohua
AU - Cai, Jianmei
AU - Mou, Xuanqin
N1 - Publisher Copyright:
© 2020 ACM.
PY - 2020/12/5
Y1 - 2020/12/5
N2 - X-ray has been widely used in medical diagnosis and other fields with the non-destructive merit. Recently, the cold cathode X-ray source based on field emission, which are different from traditional hot cathode X-ray source, have overcome the limitations of traditional X-ray source due to their small size, addressable, and integrated characteristics, making CT imaging methods can be further developed. Especially X-ray sources using ZnO nanowires as cold cathodes can densely integrate a large number of X-ray sources into flat panel devices. When we use this flat X-ray source to light up multiple sources to scan an object at the same time, small source spacing will cause inevitable projection aliasing. Therefore, we propose an image restoration algorithm for projection aliasing, and use the method of projection rearrangement to remove projection aliasing. In addition, we estimated the spectrum of the flat-panel X-ray source by solving the spectral model parameters from the attenuation data of materials of different thicknesses, and used the spectral information to simulate the effect of the proposed image restoration method on the new photon counting detector. The results of simulation experiments show the effectiveness of this method and the potential of this new imaging mode.
AB - X-ray has been widely used in medical diagnosis and other fields with the non-destructive merit. Recently, the cold cathode X-ray source based on field emission, which are different from traditional hot cathode X-ray source, have overcome the limitations of traditional X-ray source due to their small size, addressable, and integrated characteristics, making CT imaging methods can be further developed. Especially X-ray sources using ZnO nanowires as cold cathodes can densely integrate a large number of X-ray sources into flat panel devices. When we use this flat X-ray source to light up multiple sources to scan an object at the same time, small source spacing will cause inevitable projection aliasing. Therefore, we propose an image restoration algorithm for projection aliasing, and use the method of projection rearrangement to remove projection aliasing. In addition, we estimated the spectrum of the flat-panel X-ray source by solving the spectral model parameters from the attenuation data of materials of different thicknesses, and used the spectral information to simulate the effect of the proposed image restoration method on the new photon counting detector. The results of simulation experiments show the effectiveness of this method and the potential of this new imaging mode.
KW - energy spectrum imaging
KW - flat-panel source
KW - image restoration
KW - projection aliasing
UR - https://www.scopus.com/pages/publications/85114276518
U2 - 10.1145/3451421.3451423
DO - 10.1145/3451421.3451423
M3 - 会议稿件
AN - SCOPUS:85114276518
T3 - ACM International Conference Proceeding Series
SP - 5
EP - 9
BT - ISICDM 2020 - Conference Proceedings of the 4th International Symposium on Image Computing and Digital Medicine
PB - Association for Computing Machinery
T2 - 4th International Symposium on Image Computing and Digital Medicine, ISICDM 2020
Y2 - 5 December 2020 through 8 December 2020
ER -