TY - GEN
T1 - Modelling and design of a capacitive touch sensor for urinary tract infection detection at the point-of-care
AU - Barbosa, Catia
AU - Dong, Tao
N1 - Publisher Copyright:
© 2014 IEEE.
PY - 2014/11/2
Y1 - 2014/11/2
N2 - Due to great use of touchscreens in mobile telephones and other electronic devices, there has been great evolution in this technology. Its wide applicability makes the touch sensor technology suitable for detection of specific components in urine, responsible for urinary tract infection (UTI). Integration of a touch sensor in a disposable probe tip to be used in UTI detection represents a powerful tool to develop new point-of-care testing (POCT) devices. The simplified structure of an electrodes array touch screen was simulated using the software COMSOL Multiphysics to prove that capacitive based touch screens can be used for detection of UTI. Besides we assumed presence of E.coli, one of the major causes of UTI urine. Results show that global capacitance increases if an E.coli sphere is present near the active electrodes, remaining approximately constant when further apart electrodes are excited. The output simulated voltage varies according to the capacitance value, decreasing when the capacitance is increased.
AB - Due to great use of touchscreens in mobile telephones and other electronic devices, there has been great evolution in this technology. Its wide applicability makes the touch sensor technology suitable for detection of specific components in urine, responsible for urinary tract infection (UTI). Integration of a touch sensor in a disposable probe tip to be used in UTI detection represents a powerful tool to develop new point-of-care testing (POCT) devices. The simplified structure of an electrodes array touch screen was simulated using the software COMSOL Multiphysics to prove that capacitive based touch screens can be used for detection of UTI. Besides we assumed presence of E.coli, one of the major causes of UTI urine. Results show that global capacitance increases if an E.coli sphere is present near the active electrodes, remaining approximately constant when further apart electrodes are excited. The output simulated voltage varies according to the capacitance value, decreasing when the capacitance is increased.
UR - https://www.scopus.com/pages/publications/84929484139
U2 - 10.1109/EMBC.2014.6944746
DO - 10.1109/EMBC.2014.6944746
M3 - 会议稿件
C2 - 25571114
AN - SCOPUS:84929484139
T3 - 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2014
SP - 4995
EP - 4998
BT - 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2014
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2014
Y2 - 26 August 2014 through 30 August 2014
ER -