TY - GEN
T1 - Microstructures formed on a low fluorescent glass using glassy carbon molding
AU - Sasaki, T.
AU - Takahashi, M.
AU - Maeda, R.
AU - Tanaka, T.
AU - Maeno, T.
AU - Yang, Z.
PY - 2005
Y1 - 2005
N2 - We report a pattern generation method on glass using hot embossing technology. Microstructures were formed on Borofloat, a low fluorescent glass, using a glassy carbon mold. A cubic block in the size of 100 um × 100 um × 50 um is the basic testing pattern. This block was repeated on a mirror polished glassy carbon wafer with a space in the pitch of 30 um. The whole pattern area is in 15 mm × 15 mm square on this carbon mold. Both the glass wafer and the mold were heated to 655°C and the embossing was processed at 2 MPa under vacuum (0.07 Pa). The state was held for 20 min, and then the embossed piece was cooling down to 200°C naturally in the vacuum chamber. The patterns on mold were transferred compensate to the glass. Each fabrication cycle is about 1.5 hours. This method shows great potential to fabricate bio-MEMS devices efficiently with a very low cost. The main target is to fabricate the devices for highly sensitive fluorescent detection applications, which is very difficult to be realized using plastic substrates. A multi-channel pattern (with 70 um line and 400 um space) has been generated on a 20 mm square glassy carbon using a laser machine. The pattern replicated on glass chips has been demonstrated.
AB - We report a pattern generation method on glass using hot embossing technology. Microstructures were formed on Borofloat, a low fluorescent glass, using a glassy carbon mold. A cubic block in the size of 100 um × 100 um × 50 um is the basic testing pattern. This block was repeated on a mirror polished glassy carbon wafer with a space in the pitch of 30 um. The whole pattern area is in 15 mm × 15 mm square on this carbon mold. Both the glass wafer and the mold were heated to 655°C and the embossing was processed at 2 MPa under vacuum (0.07 Pa). The state was held for 20 min, and then the embossed piece was cooling down to 200°C naturally in the vacuum chamber. The patterns on mold were transferred compensate to the glass. Each fabrication cycle is about 1.5 hours. This method shows great potential to fabricate bio-MEMS devices efficiently with a very low cost. The main target is to fabricate the devices for highly sensitive fluorescent detection applications, which is very difficult to be realized using plastic substrates. A multi-channel pattern (with 70 um line and 400 um space) has been generated on a 20 mm square glassy carbon using a laser machine. The pattern replicated on glass chips has been demonstrated.
UR - https://www.scopus.com/pages/publications/33846912784
U2 - 10.1109/iembs.2005.1616149
DO - 10.1109/iembs.2005.1616149
M3 - 会议稿件
AN - SCOPUS:33846912784
SN - 0780387406
SN - 9780780387409
T3 - Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
SP - 7126
EP - 7128
BT - Proceedings of the 2005 27th Annual International Conference of the Engineering in Medicine and Biology Society, IEEE-EMBS 2005
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2005 27th Annual International Conference of the Engineering in Medicine and Biology Society, IEEE-EMBS 2005
Y2 - 1 September 2005 through 4 September 2005
ER -