TY - GEN
T1 - Microfluidic paper-based analytical devices for colorimetric detection of urinary tract infection biomarkers on adult diapers
AU - Chen, Chaohao
AU - Dong, Tao
N1 - Publisher Copyright:
© 2015 IEEE.
PY - 2015/11/4
Y1 - 2015/11/4
N2 - Urinary tract infections (UTI) are common infection diseases in elderly patients. The conventional method of detecting UTI involves the collection of significant urine samples from the elderly patients. However, this is a very difficult and time-consuming procedure. This paper addresses the development of a microfluidic paper-based analytical device (μPAD) to detect UTI from urine collected from adult diapers. The design and fabrication for the μPAD is shown. The fabrication process involves melting solid wax on top of filter paper using a hot plate, followed by pattern transfer using a mold with rubbed wax. To demonstrate the feasibility of the proposed method, the μPAD with deposited nitrite reagent had detected different concentrations of nitrite solutions from 0.5 ppm to 100 ppm spiked in urine samples. A calibration curve was obtained by plotting the gray scale intensity values against the various nitrite concentrations. The results showed that the proposed paper-based device holds great potential as low-cost, disposable solution to sensitively detect UTI markers in urine sampled from diapers.
AB - Urinary tract infections (UTI) are common infection diseases in elderly patients. The conventional method of detecting UTI involves the collection of significant urine samples from the elderly patients. However, this is a very difficult and time-consuming procedure. This paper addresses the development of a microfluidic paper-based analytical device (μPAD) to detect UTI from urine collected from adult diapers. The design and fabrication for the μPAD is shown. The fabrication process involves melting solid wax on top of filter paper using a hot plate, followed by pattern transfer using a mold with rubbed wax. To demonstrate the feasibility of the proposed method, the μPAD with deposited nitrite reagent had detected different concentrations of nitrite solutions from 0.5 ppm to 100 ppm spiked in urine samples. A calibration curve was obtained by plotting the gray scale intensity values against the various nitrite concentrations. The results showed that the proposed paper-based device holds great potential as low-cost, disposable solution to sensitively detect UTI markers in urine sampled from diapers.
UR - https://www.scopus.com/pages/publications/84953269156
U2 - 10.1109/EMBC.2015.7319732
DO - 10.1109/EMBC.2015.7319732
M3 - 会议稿件
C2 - 26737632
AN - SCOPUS:84953269156
T3 - Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
SP - 5892
EP - 5895
BT - 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2015
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2015
Y2 - 25 August 2015 through 29 August 2015
ER -