Abstract

Objective: To investigate the properties of screwbone interface of expansive pedicle screw (EPS) in osteoporotic sheep by micro-CT and histological observation. Methods: Six female sheep with bilateral ovariectomy-induced osteoporosis were employed in this experiment. After EPS insertion in each femoral condyle, the sheep were randomly divided into two groups: 3 sheep were bred for 3 months (Group A), while the other 3 were bred for 6 months (Group B). After the animals being killed, the femoral condyles with EPS were obtained, which were three-dimensionally-imaged and reconstructed by micro-CT. Histological evaluation was made thereafter. Results: The trabecular microstructure was denser at the screw-bone interface than in the distant parts in expansive section, especially within the spiral marking. In the non-expansive section, however, there was no significant difference between the interface and the distant parts. The regions of interest (ROI) adjacent to EPS were reconstructed and analyzed by micro-CT with the same thresholds. The three-dimensional (3-D) parameters, including tissue mineral density (TMD), bone volume fraction (BVF, BV/TV), bone surface/bone volume (BS/BV) ratio, trabecular thickness (Tb.Th), and trabecular separation (Th.Sp), were significantly better in expansive sections than non-expansive sections (P<0.05). Histologically, newly-formed bony trabeculae crawled along the expansive fissures and into the center of EPS. The newly-formed bones, as well as the bones at the bone-screw interface, closely contacted with the EPS and constructed four compartments. Conclusions: The findings of the current study, based on micro-CT and histological evaluation, suggest that EPS can significantly provide stabilization in osteoporotic cancellous bones.

Original languageEnglish
Pages (from-to)72-77
Number of pages6
JournalChinese Journal of Traumatology - English Edition
Volume11
Issue number2
DOIs
StatePublished - 1 Apr 2008
Externally publishedYes

Keywords

  • Expansive pedicle screws
  • Micro-CT
  • Osteoporosis
  • Screw-bone interface
  • Three-dimensional parameters