Abstract
With air and water as working fluids, the film thickness in gas-liquid two-phase stratified flow through horizontal channels is measured by using two-parallel conductance probes. Two different test sections were used. One is a rectangular channel with cross section area of 25 mm ×150 mm, which is made of plexiglass plates, and the total length is 6690 mm, the other is a circular pipe made of plexiglass tubes with an inner diameter of 50 mm, which is 6680 mm in length. Furthermore the theoretical investigation of the film thickness in gas-liquid two-phase flow was carried out by using two-fluid model. The theoretical results were compared with the experimental data, and good agreement was achieved.
| Original language | English |
|---|---|
| Pages (from-to) | 42-46 |
| Number of pages | 5 |
| Journal | Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University |
| Volume | 32 |
| Issue number | 5 |
| State | Published - 1998 |
Fingerprint
Dive into the research topics of 'Measurements and prediction of the liquid film thickness in horizontal gas-liquid two-phase separated flow'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver