Skip to main navigation Skip to search Skip to main content

Measurement of static balance for incomplete spherical superconducting rotor with compressed air

  • Fei Gao
  • , Hui Wang
  • , Xin Ning Hu
  • , Qiu Liang Wang
  • CAS - Institute of Electrical Engineering
  • University of Chinese Academy of Sciences

Research output: Contribution to journalArticlepeer-review

1 Scopus citations

Abstract

A flotation method involving the control of the unbalance orientation of a rotor is put forward to improve the measurement precision of mass imbalance of an incomplete spherical superconducting rotor. By adding additional weights within the rotor to change its quantity of the mass unbalance, this method limits the azimuth of the mass unbalance to an accurate measurable range. As the additional weights change, the observed values change simultaneously, and the mass unbalance can be derived by a relevant formula. This method can improve the measured precision without any damage to the rotor or influence on its electromagnetic and superconducting properties. The fluctuation of the measured offset is within ±6 μm, and its Z-axis component is within ±8 μm. Moreover, it can improve the working performance of some types of the devices based on the rotor greatly, and can offer some references for other balanced measurements of the machines without mechanical support for its rotor. The measurement equipment of this method is simple, precise, and its experimental period is short.

Original languageEnglish
Pages (from-to)1566-1572
Number of pages7
JournalGuangxue Jingmi Gongcheng/Optics and Precision Engineering
Volume20
Issue number7
DOIs
StatePublished - Jul 2012

Keywords

  • Flotation method
  • Incomplete spherical rotor
  • Static balance measurement
  • Superconducting rotor

Fingerprint

Dive into the research topics of 'Measurement of static balance for incomplete spherical superconducting rotor with compressed air'. Together they form a unique fingerprint.

Cite this