Skip to main navigation Skip to search Skip to main content

Measurement enhancement on two-dimensional temperature distribution of methane-air premixed flame using SMART algorithm in CT-TDLAS

  • Korea Maritime and Ocean University
  • Tokushima University

Research output: Contribution to journalArticlepeer-review

11 Scopus citations

Abstract

In this study, the temperature distribution of the Methane-Air premixed flame was measured. In order to enhance the measurement accuracy of the CT-TDLAS (Computed tomography-tunable diode laser absorption spectroscopy), the SMART (simultaneous multiplicative algebraic reconstruction technique) algorithm has been adopted. Further, the SLOS (summation of line of sight) and the CSLOS (corrective summation of line of sight) methods have been adopted to increase measurement accuracies. It has been verified that the relative error for the temperatures measured by the thermocouples and calculated by the CT-TDLAS was about 10%.

Original languageEnglish
Article number4955
JournalApplied Sciences (Switzerland)
Volume9
Issue number22
DOIs
StatePublished - 1 Nov 2019
Externally publishedYes

Keywords

  • Burner
  • Computed tomography-tunable diode laser absorption spectroscopy
  • Concentration
  • Exhaust gas
  • Methane-Air premixed flame
  • Temperature

Fingerprint

Dive into the research topics of 'Measurement enhancement on two-dimensional temperature distribution of methane-air premixed flame using SMART algorithm in CT-TDLAS'. Together they form a unique fingerprint.

Cite this