Low temperature overpressurization analysis for CPR1000

Research output: Contribution to journalArticlepeer-review

Abstract

An additional low temperature overpressure protection system which relies on the Pressurizer (PRZ) pressure relief valves has been put forward under the situation in which the Residual Heat Removal System (RHRS) is unavailable or isolated. Taking into account the risk of Reactor Pressure Vessel (RPV) brittle fracture and LOCA under cold overpressurization transients, it is urgent to strengthen the low temperature overpressure protection for in-service Pressurized Water Reactors (PWR) in China. In this paper, the simulation and analysis of two types of overpressure transients at low temperature during the shutdown process are carried out through the detailed Relap5 modeling of CPR1000. The results show that the place where the brittle fracture occurs firstly is the lower plenum. The sensitivities of the system temperature and the opening/closing time of the additional protection system's valve are analyzed. The system set point becomes more restrictive at lower coolant temperature. Additional threshold values of the PRZ pressure relief valve are given under different Effective Full Power Years (EFPY). The set point should be less than 5.5 MPa in the case of 5 EFPY and less than 3.7 MPa at 10 EFPY.The results can be applied to engineering practice, which can effectively improve the safety of CPR1000.

Original languageEnglish
Pages (from-to)145-153
Number of pages9
JournalInternational Journal of Advanced Nuclear Reactor Design and Technology
Volume3
DOIs
StatePublished - Jan 2021

Keywords

  • CPR1000
  • Heat addition
  • LTOP
  • Mass addition
  • Relief valve

Fingerprint

Dive into the research topics of 'Low temperature overpressurization analysis for CPR1000'. Together they form a unique fingerprint.

Cite this