Skip to main navigation Skip to search Skip to main content

Low-Level Electrical Stimulation of Aortic Root Ventricular Ganglionated Plexi Attenuates Autonomic Nervous System-Mediated Atrial Fibrillation

  • Hong Tao Wang
  • , Ming Xu
  • , Boyuan Fan
  • , Xiong Tao Liu
  • , Fei Fei Su
  • , Di Zeng
  • , Jun Ren
  • , Qiang Sun Zheng
  • Tangdu Hospital, Fourth Military Medical University
  • Air Force Medical University
  • University of Wyoming

Research output: Contribution to journal › Article › peer-review

2 Scopus citations

Abstract

Objectives This study investigated the effect of electrical stimulation of aortic root ventricular ganglionated plexi (GP) on atrial fibrillation (AF) inducibility. Background The ventricular GP are interconnected with atrial GP to govern heart function, although the effect of ventricular GP modification on control of AF remains unknown. Methods Effective refractory periods (ERPs) of test pulmonary veins (PVs) were measured at baseline and during high-level (HL-ES) and low-level (LL-ES) electrical stimulation of the aortic root GP. The arrhythmogenic threshold of acetylcholine and isoproterenol was determined at baseline and during HL-ES and LL-ES. Moreover, AF was induced at PVs by programmed electrical stimulation after HL-ES or LL-ES. Immunohistochemistry staining was performed to examine the autonomic activity from aortic root GP to the PVs. Results Compared with the baseline group, HL-ES of aortic root GP significantly shortened atrial ERP (95 ± 13 ms vs. 122 ± 9 ms) and PV ERP (104 ± 11 ms vs. 131 ± 12 ms); decreased the threshold concentration of AF by both acetylcholine (1.3 ± 0.2 μmol/l vs. 3.2 ± 0.3 μmol/l) and isoproterenol (0.3 ± 0.1 μmol/l vs. 1.3 ± 0.2 μmol/l); and increased the AF-inducing rate from PVs (90% vs. 30%). In contrast, LL-ES of the GP prevented the shortening of ERP and PV ERP to 125 ± 10 ms and 133 ± 11 ms, respectively; increased threshold levels of acetylcholine and isoproterenol to 5.7 ± 0.4 μmol/l and 3.2 ± 0.3 μmol/l; and decreased the AF-inducing rate to 5%. We also found that the biotinylated dextran amine-containing varicose fibers projected directly from the aortic root GP to the left PVs. Conclusions These findings suggest that autonomic innervations of left PVs partly originated from aortic root ventricular GP. Moreover, LL-ES of aortic root ventricular GP suppressed AF inducibility and arose from PVs mediated by the autonomic nervous system.

Original languageEnglish
Pages (from-to)390-397
Number of pages8
JournalJACC: Clinical Electrophysiology
Volume1
Issue number5
DOIs
StatePublished - Oct 2015
Externally publishedYes

Keywords

  • aortic root ventricular ganglionated plexi
  • atrial fibrillation
  • autonomic nervous system
  • pulmonary veins

Fingerprint

Dive into the research topics of 'Low-Level Electrical Stimulation of Aortic Root Ventricular Ganglionated Plexi Attenuates Autonomic Nervous System-Mediated Atrial Fibrillation'. Together they form a unique fingerprint.

Cite this