Skip to main navigation Skip to search Skip to main content

Logistic regression analysis of contrast-enhanced ultrasound and ultrasonic elastography in differential diagnosis of thyroid nodules

  • Yong bo Xu
  • , Hua Wang
  • , Qi Zhou
  • , Jue Jiang
  • , Wen qi Ma
  • , Xiao ying Lei
  • Xi'an Jiaotong University

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

OBJECTIVE: To evaluate the contrast-enhanced ultrasound(CEUS) and ultrasonic elastography (UE) in diagnosis of thyroid nodules by a binary Logistic regression model.

METHODS: A total 149 cases with thyroid nodules were examed by CEUS and UE and were confirmed by surgical pathology. A Logistic model was obtained on the basis of ultrasonographic features. Receiver operator characteris(ROC) curve was constructed to assess the performance of the Logistic model.

RESULTS: Four ultrasonographic features including calcification, enhancement degree, biggest perfusion strength and elastic score were finally entered into the Logistic model. The percentage of correct prediction was 91.90%.

CONCLUSION: Both CEUS and UE have high value in differential diagnosis of thyroid nodules and the Logistic regression model has high diagnostic rate.

Original languageEnglish
Pages (from-to)495-498
Number of pages4
JournalZhonghua er bi yan hou tou jing wai ke za zhi = Chinese journal of otorhinolaryngology head and neck surgery
Volume48
Issue number6
StatePublished - 1 Jun 2013

Fingerprint

Dive into the research topics of 'Logistic regression analysis of contrast-enhanced ultrasound and ultrasonic elastography in differential diagnosis of thyroid nodules'. Together they form a unique fingerprint.

Cite this