Skip to main navigation Skip to search Skip to main content

Limited view cone-beam x-ray luminescence tomography based on depth compensation and group sparsity prior

  • Peng Gao
  • , Junyan Rong
  • , Tianshuai Liu
  • , Wenli Zhang
  • , Bin Lan
  • , Xiaoping Ouyang
  • , Hongbing Lu
  • Air Force Medical University
  • Northwest Institute of Nuclear Technology

Research output: Contribution to journal › Article › peer-review

10 Scopus citations

Abstract

Significance: As a promising hybrid imaging technique with x-ray excitable nanophosphors, cone-beam x-ray luminescence computed tomography (CB-XLCT) has been proposed for in-depth biological imaging applications. In situations in which the full rotation of the imaging object (or x-ray source) is inapplicable, the x-ray excitation is limited by geometry, or a lower x-ray excitation dose is mandatory, limited view CB-XLCT reconstruction would be essential. However, this will result in severe ill-posedness and poor image quality. Aim: The aim is to develop a limited view CB-XLCT imaging strategy to reduce the scanning span and a corresponding reconstruction method to achieve robust imaging performance. Approach: In this study, a group sparsity-based reconstruction method is proposed with the consideration that nanophosphors usually cluster in certain regions, such as tumors or major organs such as the liver. In addition, depth compensation (DC) is adopted to avoid the depth inconsistency caused by a limited view strategy. Results: Experiments using numerical simulations and physical phantoms with different edge-to-edge distances were carried out to illustrate the validity of the proposed method. The reconstruction results showed that the proposed method outperforms conventional methods in terms of localization accuracy, target shape, image contrast, and spatial resolution with two perpendicular projections. Conclusions: A limited view CB-XLCT imaging strategy with two perpendicular projections and a reconstruction method based on DC and group sparsity, which is essential for fast CB-XLCT imaging and for some practical imaging applications, such as imaging-guided surgery, is proposed.

Original languageEnglish
Article number016004
JournalJournal of Biomedical Optics
Volume25
Issue number1
DOIs
StatePublished - 1 Jan 2020
Externally publishedYes

Keywords

  • depth compensation
  • group sparsity
  • ill-posed
  • limited view
  • x-ray luminescence

Fingerprint

Dive into the research topics of 'Limited view cone-beam x-ray luminescence tomography based on depth compensation and group sparsity prior'. Together they form a unique fingerprint.

Cite this