Skip to main navigation Skip to search Skip to main content

Isobaric heat capacity of [EMIM][AC] under high pressure

  • Xi'an Jiaotong University

Research output: Contribution to journalArticlepeer-review

Abstract

Ionic liquid 1-ethyl-3-methylimidazolium acetate ([EMIM][Ac]) is widely used in the process of chemical separation, but its cp data are scarce, especially in high pressure regions. A flow calorimeter is developed for the isobaric heat capacities of fluid at high pressure. The total uncertainties of temperature, pressure and isobaric heat capacity are estimated to be 0.05 K, 13 kPa and 0.98% respectively. Isobaric heat capacity of [EMIM][Ac] was measured in the temperature range from 303 K to 393 K and from 0.1 to 16 MPa. Based on the experimental results, an accurate model is proposed for predicting the isobaric heat capacity of [EMIM][Ac].

Original languageEnglish
Pages (from-to)2048-2051
Number of pages4
JournalKung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics
Volume37
Issue number10
StatePublished - 1 Oct 2016

Keywords

  • Flow calorimeter
  • High pressure
  • Ionic liquid
  • Isobaric heat capacity

Fingerprint

Dive into the research topics of 'Isobaric heat capacity of [EMIM][AC] under high pressure'. Together they form a unique fingerprint.