TY - JOUR
T1 - Investigation on insulation material morphological structure of 110 and 220 kV XLPE retired cables for reusing
AU - Xu, Yang
AU - Luo, Pan
AU - Xu, Man
AU - Sun, Tingxi
PY - 2014/8
Y1 - 2014/8
N2 - Most of the 110 and 220 kV cables are in service till the end of life, but part of them would be out of service by refurbishment. This research is focused on evaluating the cable insulation and determining whether the cable can be reused. All the cables used in this research satisfactorily passed the AC voltage and partial discharge tests. Then the fourier transform infrared spectroscopy, thermogravimetry analysis, differential scanning calorimetry, dynamic mechanical analysis, and tensile machine were used to analyze the insulation morphological structure and performance of 20 retired 110 and 220 kV crosslinked polyethylene cables obtained from the Beijing and Zhuhai districts. The results show that the structure parameters which can represent the physical change and the irreversible chemical change of cables have obvious time dependence characteristic. DSC result shows that crystallinity, melting range, and crystallization rate increase slightly with service years. DMA experiment illustrates that the temperature of mechanical loss peak, Tγ, shifts to a higher temperature while the mechanical loss increases slightly and temperature dependency of storage modulus increases with service years. The electrical treeing experiment utilized cable operated for 17 years, which is the longest operation year for the samples. Compared with new cable, the cable operated for 17 years has a slight decrease in tree initiation time and an obvious increase in tree propagation time. These experiment data show that the insulation material morphological structure is mainly stable, and the test results are also a contribution to the lifetime expectancy evaluation of the 110 and 220 kV XLPE cable.
AB - Most of the 110 and 220 kV cables are in service till the end of life, but part of them would be out of service by refurbishment. This research is focused on evaluating the cable insulation and determining whether the cable can be reused. All the cables used in this research satisfactorily passed the AC voltage and partial discharge tests. Then the fourier transform infrared spectroscopy, thermogravimetry analysis, differential scanning calorimetry, dynamic mechanical analysis, and tensile machine were used to analyze the insulation morphological structure and performance of 20 retired 110 and 220 kV crosslinked polyethylene cables obtained from the Beijing and Zhuhai districts. The results show that the structure parameters which can represent the physical change and the irreversible chemical change of cables have obvious time dependence characteristic. DSC result shows that crystallinity, melting range, and crystallization rate increase slightly with service years. DMA experiment illustrates that the temperature of mechanical loss peak, Tγ, shifts to a higher temperature while the mechanical loss increases slightly and temperature dependency of storage modulus increases with service years. The electrical treeing experiment utilized cable operated for 17 years, which is the longest operation year for the samples. Compared with new cable, the cable operated for 17 years has a slight decrease in tree initiation time and an obvious increase in tree propagation time. These experiment data show that the insulation material morphological structure is mainly stable, and the test results are also a contribution to the lifetime expectancy evaluation of the 110 and 220 kV XLPE cable.
KW - Power cable insulation
KW - aging
KW - electrthermal effects
KW - morphology
KW - trees-insulation
UR - https://www.scopus.com/pages/publications/84907371941
U2 - 10.1109/TDEI.2014.004311
DO - 10.1109/TDEI.2014.004311
M3 - 文章
AN - SCOPUS:84907371941
SN - 1070-9878
VL - 21
SP - 1687
EP - 1696
JO - IEEE Transactions on Dielectrics and Electrical Insulation
JF - IEEE Transactions on Dielectrics and Electrical Insulation
IS - 4
M1 - 6877996
ER -