Skip to main navigation Skip to search Skip to main content

Investigation of dielectric barrier discharge and dielectric barrier corona discharge in SO2 removal

  • Xi'an Jiaotong University

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

The dielectric barrier corona discharge (DBCD) in a wire-cylinder configuration and the dielectric barrier discharge (DBD) in a coaxial cylinder configuration are investigated, then the dissipated power and gas gap voltage are calculated by analyzing the measured Lissajous figure. The researching results demonstrate that the discharge current in DBD has higher pulse amplitude than in DBCD, and with the increasing applied voltage, the energy utilization factor for SO2 removal increases in DBCD but decreases in DBD due to the difference in their electric field distribution. The experiments of SO2 removal verify that in the absence of NH3 the energy utilization factor can reach 31 g/kWh in DBCD and 39 g/kWh in DBD.

Original languageEnglish
Pages (from-to)1022-1025
Number of pages4
JournalHsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University
Volume38
Issue number10
StatePublished - Oct 2004

Keywords

  • Corona discharge
  • Dielectric barrier discharge
  • Discharge power
  • SO removal

Fingerprint

Dive into the research topics of 'Investigation of dielectric barrier discharge and dielectric barrier corona discharge in SO2 removal'. Together they form a unique fingerprint.

Cite this