Skip to main navigation Skip to search Skip to main content

Influence of the primary frequency modulation of a supercritical unit on the dynamic thermal characteristics of its steam turbine

  • Shandong Electric Power Research Institute
  • Xi'an Jiaotong University
  • Xi'an Thermodynamics Research Institute Co. Ltd.

Research output: Contribution to journal › Article › peer-review

2 Scopus citations

Abstract

A mathematical model was established for supercritical units and their control systems, a software for calculating the off-design condition characteristics of the units was programmed and the law governing the influence of the primary frequency modulation on the dynamic thermal characteristics of the supercritical steam turbine was studied. By using a method combining the lumped parameters with distribution parameters, a dynamic mathematical model was established for the units and the static and dynamic characteristics of the units under various operating conditions was analyzed with the law governing the influence of the load disturbance and parameters of the control system under different operating conditions on the flow rate of the units, pressure and temperature after the regulating stage and temperature after the reheater being obtained. It has been found that with an increase of the load disturbance, whatever the units are in constant pressure and sliding pressure operation, the percentage overshoots of various physical quantities during the dynamic process are constant and changes of the temperatures in various HP, IP and LP stages of the units can be neglected. When the units are in sliding pressure operation, under the condition of the temperature at the outlet of the boiler being kept constant, with an increase of the time constant in both flow rate-pressure link and power-flow rate link, any change in the temperature after the HP regulating stage is approximately 1.5℃ and that after the reheater is about 0.2℃. Therefore, the influence of the primary frequency modulation on the dynamic characteristics of the thermal parameters in the supercritical units under various operating conditions is very small and will not affect the safety and stability of the units in operation.

Original languageEnglish
Pages (from-to)470-476
Number of pages7
JournalReneng Dongli Gongcheng/Journal of Engineering for Thermal Energy and Power
Volume29
Issue number5
StatePublished - 20 Sep 2014

Keywords

  • Constant pressure operation
  • Dynamic thermal characteristics
  • Primary frequency modulation
  • Sliding pressure operation
  • Supercritical unit

Fingerprint

Dive into the research topics of 'Influence of the primary frequency modulation of a supercritical unit on the dynamic thermal characteristics of its steam turbine'. Together they form a unique fingerprint.

Cite this