Influence of discharge gap and display-electrode width on optical and electrical characteristics of color AC-PDP

  • Xi'an Jiaotong University

Research output: Contribution to journal › Article › peer-review

Abstract

Influence of discharge gap and display-electrode width on the optical and electrical characteristics of surface-discharge color alternating current plasma display panel (AC-PDP) is experimentally studied and theoretically analyzed. The results show that the gas discharge between display electrodes in surface-discharge AC-PDP does not conform to Paschen law, viz. firing voltage is not a function of the product of gas pressure p and discharge gap g1. In the Uf-pg1 curve, the minimum firing voltage Ufmin rises, and (pg1)min shifts to a higher value with an increase in discharge gap g1. In addition, as discharge gap increases, sustaining voltage margin increases, and luminance and luminous efficiency of PDP become higher. As display-electrode width increases, average discharge current increases, and luminance gets improved, but luminous efficiency keeps unchanged. According to these results, the design methods for discharge gap and display-electrode width are summarized.

Original languageEnglish
Pages (from-to)178-181
Number of pages4
JournalZhenkong Kexue yu Jishu Xuebao/Journal of Vacuum Science and Technology
Volume22
Issue number3
StatePublished - May 2002

Keywords

  • Discharge gap
  • Display-electrode
  • Optical and electrical characteristics
  • Plasma display panel

Fingerprint

Dive into the research topics of 'Influence of discharge gap and display-electrode width on optical and electrical characteristics of color AC-PDP'. Together they form a unique fingerprint.

Cite this