Abstract
The dependence of electrochemical migration (ECM) of tin on chloride was investigated using in situ electrochemical and optical techniques. An interesting phenomenon is first found that tin dendrite grows not only in the electrolyte layer with low chloride concentration but also in the electrolyte layer with high chloride concentration, although it is generally suggested that the growth of tin dendrite through ECM is not available in solution with high chloride concentration. Mechanisms have been proposed to explain the ECM of tin in the electrolyte layer with various chloride concentrations.
| Original language | English |
|---|---|
| Pages (from-to) | 63-68 |
| Number of pages | 6 |
| Journal | Electrochemistry Communications |
| Volume | 27 |
| DOIs | |
| State | Published - Feb 2013 |
| Externally published | Yes |
Keywords
- Chloride
- Dendrite growth
- Electrochemical migration
- Thin electrolyte layer
- Tin
Fingerprint
Dive into the research topics of 'In situ study the dependence of electrochemical migration of tin on chloride'. Together they form a unique fingerprint.Cite this