TY - JOUR
T1 - IMU Motion Capture Method with Adaptive Tremor Attenuation in Teleoperation Robot System
AU - Zhu, Huijin
AU - Li, Xiaoling
AU - Wang, Long
AU - Chen, Zhangyi
AU - Shi, Yueyang
AU - Zhen, Shuai
AU - Li, Min
N1 - Publisher Copyright:
© 2022 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2022/5/1
Y1 - 2022/5/1
N2 - Teleoperation robot systems can help humans perform tasks in unstructured environments. However, non-intuitive control interfaces using only a keyboard or joystick and physiological tremor reduce the performance of teleoperation. This paper presents an intuitive control interface based on the wearable device gForcePro+ armband. Two gForcePro+ armbands are worn at the centroid of the upper arm and forearm, respectively. Firstly, the kinematics model of the human arm is established, and the inertial measurement units (IMUs) are used to capture the position and orientation information of the end of the arm. Then, a regression model of angular transformation is developed for the phenomenon that the rotation axis of the torsion joint is not perfectly aligned with the limb segment during motion, which can be applied to different individuals. Finally, to attenuate the physiological tremor, a variable gain extended Kalman filter (EKF) fusing sEMG signals is developed. The described control interface shows good attitude estimation accuracy compared to the VICON optical capture system, with an average angular RMSE of 4.837° ± 1.433°. The performance of the described filtering method is tested using the xMate3 Pro robot, and the results show it can improve the tracking performance of the robot and reduce the tremor.
AB - Teleoperation robot systems can help humans perform tasks in unstructured environments. However, non-intuitive control interfaces using only a keyboard or joystick and physiological tremor reduce the performance of teleoperation. This paper presents an intuitive control interface based on the wearable device gForcePro+ armband. Two gForcePro+ armbands are worn at the centroid of the upper arm and forearm, respectively. Firstly, the kinematics model of the human arm is established, and the inertial measurement units (IMUs) are used to capture the position and orientation information of the end of the arm. Then, a regression model of angular transformation is developed for the phenomenon that the rotation axis of the torsion joint is not perfectly aligned with the limb segment during motion, which can be applied to different individuals. Finally, to attenuate the physiological tremor, a variable gain extended Kalman filter (EKF) fusing sEMG signals is developed. The described control interface shows good attitude estimation accuracy compared to the VICON optical capture system, with an average angular RMSE of 4.837° ± 1.433°. The performance of the described filtering method is tested using the xMate3 Pro robot, and the results show it can improve the tracking performance of the robot and reduce the tremor.
KW - EKF
KW - IMU
KW - Physiological tremor
KW - Regression model
KW - SEMG signal
KW - Teleoperation system
UR - https://www.scopus.com/pages/publications/85129991506
U2 - 10.3390/s22093353
DO - 10.3390/s22093353
M3 - 文章
C2 - 35591043
AN - SCOPUS:85129991506
SN - 1424-8220
VL - 22
JO - Sensors (Switzerland)
JF - Sensors (Switzerland)
IS - 9
M1 - 3353
ER -