TY - GEN
T1 - Improved method of quantitative steady-state security assessment based on fast elimination of redundant transmission capacity constraints
AU - Li, Xuan
AU - Zhai, Qiaozhu
AU - Yuan, Wei
AU - Liu, Jiebing
N1 - Publisher Copyright:
© 2015 IEEE.
PY - 2015/7/17
Y1 - 2015/7/17
N2 - Steady-state security analysis is of great importance to power systems. Steady-state security region (SSR) is a region-wise method that could improve the efficiency of steady-state security analysis. Based on SSR, steady-state security distance (SSD) was proposed in literature and SSD provides a quantitative tool for security assessment on a current operation point (OP) or operational state. However, a large scale optimization problem with many constraints must be solved when calculating SSD. In this paper, an improved method for calculating SSD is presented based on fast elimination of redundant transmission capacity constraints. The main idea is to use an analytic method instead of solving an optimization problem to get an over estimation on the maximal power flow on each transmission line, and then compare the result with the line capacity to identify whether the constraint is redundant. By using this method, the problem for calculating SSD is greatly simplified. Numerical tests are performed and the results are satisfactory.
AB - Steady-state security analysis is of great importance to power systems. Steady-state security region (SSR) is a region-wise method that could improve the efficiency of steady-state security analysis. Based on SSR, steady-state security distance (SSD) was proposed in literature and SSD provides a quantitative tool for security assessment on a current operation point (OP) or operational state. However, a large scale optimization problem with many constraints must be solved when calculating SSD. In this paper, an improved method for calculating SSD is presented based on fast elimination of redundant transmission capacity constraints. The main idea is to use an analytic method instead of solving an optimization problem to get an over estimation on the maximal power flow on each transmission line, and then compare the result with the line capacity to identify whether the constraint is redundant. By using this method, the problem for calculating SSD is greatly simplified. Numerical tests are performed and the results are satisfactory.
KW - Linear Programming
KW - Redundant Constraints
KW - Steady-State Security Distance
KW - Steady-State Security Region
UR - https://www.scopus.com/pages/publications/84945565004
U2 - 10.1109/CCDC.2015.7162675
DO - 10.1109/CCDC.2015.7162675
M3 - 会议稿件
AN - SCOPUS:84945565004
T3 - Proceedings of the 2015 27th Chinese Control and Decision Conference, CCDC 2015
SP - 4242
EP - 4246
BT - Proceedings of the 2015 27th Chinese Control and Decision Conference, CCDC 2015
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 27th Chinese Control and Decision Conference, CCDC 2015
Y2 - 23 May 2015 through 25 May 2015