Abstract
Correction of current–voltage ( I-V ) curves measured under field operating conditions is crucial for energy yield prediction and power degradation assessment of photovoltaic (PV) modules. However, achieving high-accuracy results has been a problem due to the large uncertainty in outdoor measurement and correction. In this paper, the correction accuracy of measured I-V curves for different PV modules using correction procedure 4 (CP4) in IEC 60891 is investigated. For the first time, it is found that, for different PV modules, the correction accuracy is related to the voltage region used to calculate series resistance. To further elucidate the effect of series resistance on correction accuracy across different modules, the high-voltage region specified in IEC 60891 is divided into three sub-regions, i.e., the region close to the maximum power voltage (RC Vm ), the region between the maximum power voltage and the open-circuit voltage (RC Vm - Voc ), and the region close to the open-circuit voltage (RC Voc ). The calculated series resistances are termed Rs (RC Vm ), Rs (RC Vm - Voc ), and Rs (RC Voc ) for these sub-regions. Then, the correction accuracies of CP4 for TOPCon and HJT modules are compared. The results show that, for TOPCon modules, the minimum rRMSE of Pm is 3.31% when Rs (RC Voc ) is used for correction. Compared with the rRMSE obtained with Rs (RC Vm ), this value is reduced by 7.49%. In contrast, for HJT modules, the minimum rRMSE of Pm is 1.60% when Rs (RC Vm ) is used, which is 1.15% lower than that obtained with Rs (RC Voc ). This paper significantly improves the accuracy and on-site applicability of correction procedures in IEC 60891.
| Original language | English |
|---|---|
| Article number | 115241 |
| Journal | Solar Energy |
| Volume | 320 |
| DOIs | |
| State | Published - Dec 2026 |
| Externally published | Yes |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 7 Affordable and Clean Energy
Keywords
- Correction accuracy
- Current-voltagecurves
- High-voltage region
- Photovoltaic modules
- Series resistance
Fingerprint
Dive into the research topics of 'Improved correction accuracy of measured I–V characteristics for TOPCon and HJT photovoltaic modules'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver