Abstract

A novel approach has been developed for accurate and efficient shutdown dose rate (SDDR) calculations on fusion reactor devices. The new approach is based on an assumption of linear relationship between the mono-energetic neutron flux and the decay gamma source, thus the coefficients between them can be obtained for every materials and neutron energy groups through an inventory calculation. These coefficients are used in an extended version of MCNP code to perform decay gamma transport calculation. Decay gamma generated in multiple cooling time steps can be simulated together with the neutron transport calculation. This new approach has been successfully verified through the comparison with the JET shutdown dose rate measurements, R2S and D1S results. The results obtained demonstrate the reliability and efficiency of the new approach in estimation of the SDDR in fusion devices.

Original languageEnglish
Pages (from-to)498-502
Number of pages5
JournalFusion Engineering and Design
Volume136
DOIs
StatePublished - Nov 2018

Keywords

  • D1S
  • MCNP
  • R2S
  • Shutdown dose rate

Fingerprint

Dive into the research topics of 'Hybrid Monte Carlo approach for accurate and efficient shutdown dose rate calculation'. Together they form a unique fingerprint.

Cite this