High precision time jitter measurement for large multi-beam laser facility

  • Zhilin Li
  • , Xiao Wang
  • , Jie Mu
  • , Yanlei Zuo
  • , Song Zhou
  • , Qihua Zhu
  • , Jingqin Su
  • , Kainan Zhou
  • , Tianen Li
  • , Hongzhong Liu

Research output: Contribution to journalArticlepeer-review

2 Scopus citations

Abstract

The time jitter should be detected and controlled accurately for multi-beam laser facility. In this paper, a spectral interferometry method is used to measure the time jitter between beams of the typical large laser facility SG-Ⅲ prototype in the running state. The basic principle to measure the time jitter using spectral interferometry is investigated theoretically. Several key parameters for measurement accuracy are analyzed. Experimental results prove that the spectral interferometry method applied to beam time jitter measurement is effective.

Original languageEnglish
Article number111001
JournalQiangjiguang Yu Lizishu/High Power Laser and Particle Beams
Volume27
Issue number11
DOIs
StatePublished - 1 Nov 2015

Keywords

  • High-precision detection
  • Large laser facility
  • Spectral interferometry
  • Time jitter

Fingerprint

Dive into the research topics of 'High precision time jitter measurement for large multi-beam laser facility'. Together they form a unique fingerprint.

Cite this