TY - JOUR
T1 - Heat Transfer Enhancement of Partially Serrated Twisted Finned Tube Bank
AU - Wei, Hongyu
AU - Cong, Tao
AU - Jiang, Chen
AU - Zhou, Wenxue
AU - Bai, Bofeng
N1 - Publisher Copyright:
© 2023 Taylor & Francis Group, LLC.
PY - 2023
Y1 - 2023
N2 - Due to the large thermal resistance on the airside of the air-cooled heat exchangers, it is necessary to improve heat transfer performance and reduce flow resistance by improving the fin structure. In this paper, partially serrated finned tube bank was proposed and numerically investigated. The experimental system of finned tube bank was built to verify the correctness of the numerical simulation. The finned tube bank is twisted and serrated on the windward side to enhance heat transfer. Moreover, the non-grooved sector region on the leeward side reduces the flow resistance and improves the temperature uniformity of the fins. The effects of fin twisting of the windward side and non-grooving angle of the leeward side were explored. Nusselt number and friction factor decrease as the leeward non-grooving sector region increases. The correlations of Nusselt number and friction factor were derived based on the simulation results of partially serrated twisted finned tube banks with 120° non-grooving region on the leeward side. Nusselt number, friction factor and comprehensive heat transfer coefficient of partially serrated twisted finned tube bank are 13.3%, 13.0% and 10.5% higher than that of annular finned tube bank with Reynolds number from 6200 to 20,600, respectively.
AB - Due to the large thermal resistance on the airside of the air-cooled heat exchangers, it is necessary to improve heat transfer performance and reduce flow resistance by improving the fin structure. In this paper, partially serrated finned tube bank was proposed and numerically investigated. The experimental system of finned tube bank was built to verify the correctness of the numerical simulation. The finned tube bank is twisted and serrated on the windward side to enhance heat transfer. Moreover, the non-grooved sector region on the leeward side reduces the flow resistance and improves the temperature uniformity of the fins. The effects of fin twisting of the windward side and non-grooving angle of the leeward side were explored. Nusselt number and friction factor decrease as the leeward non-grooving sector region increases. The correlations of Nusselt number and friction factor were derived based on the simulation results of partially serrated twisted finned tube banks with 120° non-grooving region on the leeward side. Nusselt number, friction factor and comprehensive heat transfer coefficient of partially serrated twisted finned tube bank are 13.3%, 13.0% and 10.5% higher than that of annular finned tube bank with Reynolds number from 6200 to 20,600, respectively.
UR - https://www.scopus.com/pages/publications/85146228730
U2 - 10.1080/01457632.2022.2164682
DO - 10.1080/01457632.2022.2164682
M3 - 文章
AN - SCOPUS:85146228730
SN - 0145-7632
VL - 44
SP - 2079
EP - 2090
JO - Heat Transfer Engineering
JF - Heat Transfer Engineering
IS - 21-22
ER -