Experimental investigation on the heat transfer characteristics of superheat vapor through a new designed moisture separator reheater with “super-low” finned-tube bundles for Generation III+ nuclear power plant, was carried out based on a 5*30 tube bundle test section. Impacts of the vapor mass flow rates are analyzed on the heat transfer characteristics of superheat vapor through the finned-tube bundle. A group of experiments are reviewed on single-phase fluid flowing across the triangular super-low finned-tube bundles whose fin heights are less than 2.75 mm and ratios of fin height to fin diameter are from 0.05 to 0.15. Combining the presented experimental data with the other open published data for single-phase turbulent gases flowing across triangular super-low finned-tube, a new heat transfer correlation is proposed for the MSRs super-low finned-tube bundles, which shows better accuracy and has wider Reynolds number range in application.

Original languageEnglish
Pages (from-to)368-376
Number of pages9
JournalNuclear Engineering and Design
Volume341
DOIs
StatePublished - Jan 2019

Keywords

  • Heat transfer
  • Moisture separator reheater
  • Super-low finned-tube bundle
  • Superheated vapor

Fingerprint

Dive into the research topics of 'Heat transfer characteristics in super-low finned-tube bundles of moisture separator reheaters'. Together they form a unique fingerprint.