Abstract
Experimental investigation on the heat transfer characteristics of superheat vapor through a new designed moisture separator reheater with “super-low” finned-tube bundles for Generation III+ nuclear power plant, was carried out based on a 5*30 tube bundle test section. Impacts of the vapor mass flow rates are analyzed on the heat transfer characteristics of superheat vapor through the finned-tube bundle. A group of experiments are reviewed on single-phase fluid flowing across the triangular super-low finned-tube bundles whose fin heights are less than 2.75 mm and ratios of fin height to fin diameter are from 0.05 to 0.15. Combining the presented experimental data with the other open published data for single-phase turbulent gases flowing across triangular super-low finned-tube, a new heat transfer correlation is proposed for the MSRs super-low finned-tube bundles, which shows better accuracy and has wider Reynolds number range in application.
| Original language | English |
|---|---|
| Pages (from-to) | 368-376 |
| Number of pages | 9 |
| Journal | Nuclear Engineering and Design |
| Volume | 341 |
| DOIs | |
| State | Published - Jan 2019 |
Keywords
- Heat transfer
- Moisture separator reheater
- Super-low finned-tube bundle
- Superheated vapor