Generative restoration for cardiac PET attenuation correction: a two-stage 3D DDIM framework optimizing fidelity and clinical controllability

  • Junhang Deng
  • , Hao Sun
  • , Haifeng Wang
  • , Xiaotong Hong
  • , Weiping Xu
  • , Fan Wang
  • , Jianhua Ma
  • , Chunfeng Lian
  • , Lijun Lu
  • Xi'an Jiaotong University
  • Southern Medical University
  • Guangdong Academy of Medical Sciences
  • Guangdong Artificial Intelligence and Digital Economy Laboratory - Guangzhou

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: This study aims to develop a two-stage 3D denoising diffusion implicit model (DDIM) framework for CT-free attenuation correction in cardiac PET imaging, enabling direct generation of attenuation-corrected (AC) images from non-attenuation-corrected (NAC) PET scans. The method is comprehensively validated using both [18F]FDG PET and [13N]ammonia cardiac PET datasets to demonstrate its clinical applicability across different perfusion and metabolic imaging protocols. Methods: The framework employs a two-stage approach: (1) a noise-to-image DDIM was first pretrained on all available AC images (i.e., no need of paired NACs) to learn a diverse AC distributions, enabling the high-fidelity generation of AC images with varying appearances; (2) the pretrained model was fine-tuned with a limited set of paired NAC-AC images to form a conditional DDIM, ensuring anatomically aligned, controllable generation. The model architecture uses a 3D U-Net, trained on 224 paired NAC-AC and 396 unpaired AC images for [18F]FDG, and 608 paired NAC-AC images and 885 unpaired AC images for [13N]ammonia. Performance was evaluated through quantitative metrics (including NMAE, NRMSE, SSIM and PSNR) and visual assessment. Results: The proposed two-stage DDIM framework achieved excellent agreement with clinical CT-based attenuation correction (CT-AC), demonstrating superior correlation (slope = 0.78, = 0.95 for [18F]FDG; slope = 0.99, = 0.91 for [13N]ammonia) and lower errors compared to existing approaches. Ablation studies confirmed the benefits of both the two-stage training strategy and the incorporation of unpaired AC images, as evidenced by narrower confidence intervals in Bland-Altman analysis and reduced percentage errors. Conclusion: The two-stage 3D DDIM framework achieves performance comparable to clinical CT-AC while effectively leveraging unpaired data, demonstrating significant potential for robust cardiac PET attenuation correction.

Original languageEnglish
Article number21
JournalEJNMMI Physics
Volume13
Issue number1
DOIs
StatePublished - Dec 2026

Keywords

  • Attenuation correction
  • Cardiac PET