Abstract
In APWR reactor coolant pump is both directly attached to steam generator channel head and elbow is eliminated. And nozzle dams are mounted on steam generator channel head outlet chamber. So the flow vector within steam generator channel head outlet nozzle is quite complex. Flow characteristics experimental study within connection between steam generator channel head and pump suction has been done by air test without nozzle dams and water loop test with them respectively. It is shown that axial vortex is eliminated and velocity is uniform in outlet section of outlet nozzle of steam generator channel head.
| Original language | English |
|---|---|
| Pages (from-to) | 38-42 |
| Number of pages | 5 |
| Journal | Hedongli Gongcheng/Nuclear Power Engineering |
| Volume | 23 |
| Issue number | SUPPL. |
| State | Published - May 2002 |
| Externally published | Yes |
Keywords
- APWR
- Channel head
- Flow characteristics
- Outlet nozzle dam
- Steam generator
Fingerprint
Dive into the research topics of 'Flow characteristics experimental study within connection between steam generator channel head and pump suction'. Together they form a unique fingerprint.Cite this