Abstract

With the development of wind power industry, early detection and diagnosis of incipient faults are desirable for the wind generators. A suitable model enables generator faults to be simulated and it is particularly useful for gaining an insight into their dynamic behavior and electro-mechanical interaction. In this paper a model of DFIG (Doubly-Fed Induction Generator) affected by stator inter-turn short circuit fault is presented. The mathematical model is established to simulate healthy and inter-turn fault conditions based on synchronous rotating reference frame. In the simulation, the negative-sequence component of stator currents and phase differences between any two phases are as detection features. The results of the simulation confirmed the validity of the model.

Original languageEnglish
Title of host publicationProceedings of 2014 International Symposium on Electrical Insulating Materials, ISEIM 2014
PublisherInstitute of Electrical Engineers of Japan
Pages233-236
Number of pages4
ISBN (Print)9784886860866
DOIs
StatePublished - 2014
Event2014 International Symposium on Electrical Insulating Materials, ISEIM 2014 - Niigata, Japan
Duration: 1 Jun 2014 → 5 Jun 2014

Publication series

NameProceedings of the International Symposium on Electrical Insulating Materials

Conference

Conference2014 International Symposium on Electrical Insulating Materials, ISEIM 2014
Country/TerritoryJapan
CityNiigata
Period1/06/14 → 5/06/14

Keywords

  • Current Signature Analysis
  • DFIG
  • Negative-sequence Current
  • Phase Differences
  • Turn-to-turn Short Circuit

Fingerprint