Skip to main navigation Skip to search Skip to main content

Experiments and predictions for severe slugging of gas-liquid two-phase flows in a long-distance pipeline-riser system

  • Yingjie Chang
  • , Qiang Xu
  • , Suifeng Zou
  • , Xiangyuan Zhao
  • , Quanhong Wu
  • , Yechun Wang
  • , Dominique Thévenin
  • , Liejin Guo
  • Chang'an University
  • Xi'an Jiaotong University
  • Otto von Guericke University Magdeburg

Research output: Contribution to journal › Article › peer-review

22 Scopus citations

Abstract

Experiments concerning the flow regimes observed in gas-liquid two-phase flows in a long-distance pipeline-riser system were carried out and analyzed in this paper. The test loop with 0.075 m inner diameter consisted of a 314 m horizontal pipeline, followed by a 25 m downward-inclined pipe, and finally a 21.5 m riser pipe. An industrial-scale global flow regime map including 5 flow regimes was derived from differential pressure measurements in the riser and was used as a reference for improvements. Electrical capacitance volume tomography installed in the horizontal section was used to reconstruct the phase interface and calculate the average gas void fraction (GVF). An appropriate model for this system was selected by comparing the experimental GVF with different, widely used models. The occurrence of severe slugging flow (SS) can be predicted accurately using an improved model involving additional corrections that consider pipeline length, accurate GVF calculation, and gas density. This study supports the development of a suitable SS prediction model enabling safe design, operation, and control of practical systems.

Original languageEnglish
Article number117636
JournalOcean Engineering
Volume301
DOIs
StatePublished - 1 Jun 2024

Keywords

  • Electrical capacitance volume tomography
  • Flow regime
  • Pipeline-riser
  • Severe slugging
  • Void fraction

Fingerprint

Dive into the research topics of 'Experiments and predictions for severe slugging of gas-liquid two-phase flows in a long-distance pipeline-riser system'. Together they form a unique fingerprint.

Cite this