Skip to main navigation Skip to search Skip to main content

Experimental study on heat transfer and pressure drop of supercritical CO2 cooled in a large tube

  • Xi'an Jiaotong University

Research output: Contribution to journal › Article › peer-review

166 Scopus citations

Abstract

In order to reveal the heat transfer and pressure drop characteristics of supercritical CO2 cooled in the large diameter tube, an experimental system was established. The heat transfer and pressure drop performances of CO2 cooled in horizontal tubes having inner diameters of 4, 6 and 10.7 mm were experimentally investigated. The effects of the CO2 mass flow rate, inlet pressure, mean bulk temperature and tube diameter on the heat transfer coefficient and pressure drop were examined. The results show that the tube diameter significantly affects the heat transfer performance. As a consequence, when the universal heat transfer correlations for the small diameter tube are used to predict the heat transfer coefficient of CO 2 in a large diameter tube, the predicted results present obvious deviation compared to the experimental results. Then based on the experimental data, a new heat transfer correlation for the large diameter tube was proposed. The maximum error between the predicted results of the new correlation and the experimental data is ±15%.

Original languageEnglish
Pages (from-to)307-315
Number of pages9
JournalApplied Thermal Engineering
Volume70
Issue number1
DOIs
StatePublished - 5 Sep 2014

Keywords

  • Heat transfer
  • Large diameter tube
  • New correlation
  • Pressure drop

Fingerprint

Dive into the research topics of 'Experimental study on heat transfer and pressure drop of supercritical CO2 cooled in a large tube'. Together they form a unique fingerprint.

Cite this