Experimental study of the effect of different oxidant on PEMFC performance

Research output: Contribution to journalArticlepeer-review

5 Scopus citations

Abstract

The performance of PEMFC with pure oxygen or air as oxidant is experimentally compared. The reaction area of the PEMFC is 9 cm2, and the conventional parallel flow field is used. The experimental results show that the performance and limited current density of the PEMFC are enhanced with increasing operational temperature. Under the condition of present experiment, the anode stoichiometry/cathode stoichiometry should be larger than 1.5/3.0 with oxygen as oxidant, and the two parameters should be larger than 3.0/6.0 with air as oxidant. Compared with the condition of air as oxidant, the PEMFC performance can be significant improved with pure oxygen as oxidant. Therefore, it is suggested that the pure oxygen should be the preferred oxidant.

Original languageEnglish
Pages (from-to)496-498
Number of pages3
JournalKung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics
Volume28
Issue number3
StatePublished - May 2007

Keywords

  • Oxidant
  • Parallel flow field
  • Performance of PEMFC
  • Stoichiometry

Fingerprint

Dive into the research topics of 'Experimental study of the effect of different oxidant on PEMFC performance'. Together they form a unique fingerprint.

Cite this