Abstract

Based on the principle that a large electric energy is absorbed during the transformation from an antiferroelectric phase to a ferroelectric phase, the regulation of electric pulse by antiferroelectric adjuster is studied. The operation voltage was applied as a rectangular pulse of 50 kV amplitude and 3.75 μs width, and the antiferroelectric adjuster was made up by lead zirconate stannate titannate ceramics. Experimental results displayed that the electrical pulse crest at rising edge was undercut, and the trough at trailing edge was padded, and the electrical pulse was smoothed expectably. The measured electric hysteresis loop indicated that the transformation between antiferroelectric and ferroelectric phase took place by the action of the voltage pulse.

Original languageEnglish
Pages (from-to)1296-1298
Number of pages3
JournalHsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University
Volume37
Issue number12
StatePublished - Dec 2003

Keywords

  • Adjuster
  • Antiferroelectrics
  • Phase transitions induced with electric field
  • Regulation of high voltage electrical pulse

Fingerprint

Dive into the research topics of 'Experimental study of the antiferroelectric adjuster on high voltage pulse regulation'. Together they form a unique fingerprint.