Abstract
A primary experimental research on the temperature difference between the phases is performed in the supersonic steam and liquid two phase flow in the steam inject. As the thermal resistance in the direct contact heat transfer between steam and cool water, there exists obviously the value of temperature difference. It increases with the flow ratio of water to steam, but keeps constant while the flow ratio is greater than a specific value. It reaches its minimum value at a critical mass flow rate. The results are both theoretically and practically valuable.
| Original language | English |
|---|---|
| Pages (from-to) | 109-112 |
| Number of pages | 4 |
| Journal | Hedongli Gongcheng/Nuclear Power Engineering |
| Volume | 25 |
| Issue number | 2 |
| State | Published - Apr 2004 |
Keywords
- Condensation
- Steam-water two phase flow
- Supersonic
- Temperature difference in heat transfer