Abstract
The flow and condensation heat transfer of supersonic steam jet immerged in subcool water was investigated experimentally. The inlet pressure of steam was at the range of 0.20-0.40 MPa and the temperature of subcool water was 27°C. The experimental and analytical results show that: the flow region consists of four different parts, namely steam plume, steam-water interface, steam-water mixing layer and pure water; With the increase of inlet steam pressure at the range of 0.20-0.40 MPa, there are three kinds of steam plume, namely conical-elliptical double layers, conical and elliptical steam plumes, and the non-dimension penetration length of steam plume linearly increases from 2.20 to 4.20 while the condensation heat transfer coefficient slowly decreases from 0.80 to 0.67 MW/(m2;·°C).
| Original language | English |
|---|---|
| Pages (from-to) | 68-70 |
| Number of pages | 3 |
| Journal | Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics |
| Volume | 28 |
| Issue number | 1 |
| State | Published - Jan 2007 |