Experimental measurement of velocity dispersion and wave attenuation at seismic frequency

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

The indispensable stability and repeatability of experimental data is crucial, so we will first quantitatively calibrate our low frequency system and make the error analysis, then aluminium and attenuated materials (Lucite) are measured to test the accuracy of the low frequency system. Comparing with other published results, we can see that the measured results are repetitive and stable.

Original languageEnglish
Title of host publication79th EAGE Conference and Exhibition 2017
PublisherEuropean Association of Geoscientists and Engineers, EAGE
ISBN (Electronic)9789462822177
StatePublished - 2017
Event79th EAGE Conference and Exhibition 2017: Energy, Technology, Sustainability - Time to Open a New Chapter - Paris, France
Duration: 12 Jun 201715 Jun 2017

Publication series

Name79th EAGE Conference and Exhibition 2017

Conference

Conference79th EAGE Conference and Exhibition 2017: Energy, Technology, Sustainability - Time to Open a New Chapter
Country/TerritoryFrance
CityParis
Period12/06/1715/06/17