TY - JOUR
T1 - Experimental investigation on the malfunction characteristics of the two-phase ejector in a typical enhanced refrigeration system
AU - Bai, Tao
AU - Lu, Yu
AU - Wan, Jiahao
AU - Yu, Jianlin
N1 - Publisher Copyright:
© 2024 Elsevier Ltd
PY - 2025/3/1
Y1 - 2025/3/1
N2 - In this paper, experimental research was conducted to explore ejector malfunctions caused by varying structural and operating parameters in the ejector outlet split ejector refrigeration system. Effective methods and strategies to mitigate ejector failure were proposed. The results indicated that inappropriate structural parameters led to ejector failure or instability. A smaller nozzle throat diameter and excessively large or small NXP values caused entrainment malfunction but not obvious pressure lift malfunctions. Conversely, a smaller mixing section diameter resulted in pressure lift malfunctions. The effect of the operating parameters on mass entrainment failures or instability was discussed. Smaller electronic expansion valve openings led to significant mass entrainment issues, and the ejector's instability became more pronounced with higher evaporator heat loads. The sensitivity of the electronic expansion valve opening to causing ejector malfunctions varied with different nozzle throat diameters. Throat diameters of 0.7 mm and 0.9 mm corresponded to TOP values of 10 % and 5 % for ejector failure, respectively. Strategies to address ejector entrainment malfunction or instability were studied. Increasing the electronic expansion valve opening effectively suppressed ejector failure, while merely adjusting compressor speed did not. A combined approach of increasing compressor speed and electronic expansion valve opening quickly resolved ejector malfunctions.
AB - In this paper, experimental research was conducted to explore ejector malfunctions caused by varying structural and operating parameters in the ejector outlet split ejector refrigeration system. Effective methods and strategies to mitigate ejector failure were proposed. The results indicated that inappropriate structural parameters led to ejector failure or instability. A smaller nozzle throat diameter and excessively large or small NXP values caused entrainment malfunction but not obvious pressure lift malfunctions. Conversely, a smaller mixing section diameter resulted in pressure lift malfunctions. The effect of the operating parameters on mass entrainment failures or instability was discussed. Smaller electronic expansion valve openings led to significant mass entrainment issues, and the ejector's instability became more pronounced with higher evaporator heat loads. The sensitivity of the electronic expansion valve opening to causing ejector malfunctions varied with different nozzle throat diameters. Throat diameters of 0.7 mm and 0.9 mm corresponded to TOP values of 10 % and 5 % for ejector failure, respectively. Strategies to address ejector entrainment malfunction or instability were studied. Increasing the electronic expansion valve opening effectively suppressed ejector failure, while merely adjusting compressor speed did not. A combined approach of increasing compressor speed and electronic expansion valve opening quickly resolved ejector malfunctions.
KW - Experimental investigation
KW - Malfunction
KW - Operating conditions
KW - Structural parameters
KW - Two-phase Ejector
UR - https://www.scopus.com/pages/publications/85212837902
U2 - 10.1016/j.applthermaleng.2024.125204
DO - 10.1016/j.applthermaleng.2024.125204
M3 - 文章
AN - SCOPUS:85212837902
SN - 1359-4311
VL - 262
JO - Applied Thermal Engineering
JF - Applied Thermal Engineering
M1 - 125204
ER -