Skip to main navigation Skip to search Skip to main content

Experimental investigation of the instantaneous mass transfer coefficient at steam-liquid interface during water film flash evaporation in closed chamber

  • Xi'an Jiaotong University

Research output: Contribution to journal › Article › peer-review

9 Scopus citations

Abstract

On the basis of the membrane penetration theory, an experimental investigation of the instantaneous mass transfer coefficient at the steam-liquid interface during water film flash evaporation was conducted. The range of the height and the superheat of water film, and the pressure of water in the vacuum chamber was 20-100 mm, 10-20°C, and 0.005-0.015 MPa, respectively. The results show that the mass transfer coefficient varies from 0.08 m/s to 16.77m/s under the experimental conditions. The coefficient decreases with the increase of the initial superheat or the initial height of water film. However, during the flash evaporation, the instantaneous mass transfer coefficient decreases quickly with the decrease of the height of water film or the increase of the pressure in the vacuum chamber.

Original languageEnglish
Pages (from-to)515-518+541
JournalHsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University
Volume42
Issue number5
StatePublished - May 2008

Keywords

  • Flash evaporation
  • Height of water film
  • Mass transfer coefficient
  • Steam-liquid interface
  • Superheat

Fingerprint

Dive into the research topics of 'Experimental investigation of the instantaneous mass transfer coefficient at steam-liquid interface during water film flash evaporation in closed chamber'. Together they form a unique fingerprint.