Abstract
For Fluoride-salt-cooled High-temperature Reactors (FHRs), a pebble bed experimental facility with internal heat generation is set up, using the Dowtherm A as the simulant fluid. Dowtherm A can match the Prandtl number of FLiBe of 520–700 °C at a low temperature range of 45–105 °C. The effects of inlet temperatures, porosity and mass flow rate are investigated on the flow and convective heat transfer characteristics. A criterion is determined for the flow regime transition from the transitional to turbulent flow. The existing correlations are unable to predict the Blake-type friction factor in the transitional flow and show mixed performance in the turbulent flow. The present empirical correlations generally underestimate the convective heat transfer coefficients of the high-Prandtl-number fluid in the pebble bed. New correlations are proposed for predicting the flow and convective heat transfer coefficients with Prandtl number at 14–19 and Reynolds number at 90–2500.
| Original language | English |
|---|---|
| Pages (from-to) | 48-57 |
| Number of pages | 10 |
| Journal | Applied Thermal Engineering |
| Volume | 145 |
| DOIs | |
| State | Published - 25 Dec 2018 |
Keywords
- Experimental investigation
- Fluoride-salt-cooled high-temperature reactors
- High-Prandtl-number fluid
- Pebble bed
Fingerprint
Dive into the research topics of 'Experimental investigation of flow and convective heat transfer on a high-Prandtl-number fluid through the nuclear reactor pebble bed core'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver