Experimental investigation into the performance of a direct refrigerant cooling battery thermal management system under key control parameters

  • Yang Zhao
  • , Chengcheng Luo
  • , Chun Wang
  • , Liushuai Li
  • , Shuping Wang
  • , Dou An
  • , Huan Xi
  • Xi'an Jiaotong University
  • Shenzhen Precise Testing Technology Co., Ltd.
  • Xi'an Jiaotong University

Research output: Contribution to journal › Article › peer-review

Abstract

The direct refrigerant cooling battery thermal management system (DRC-BTMS) has attracted significant interest owing to its superior heat transfer efficiency. However, unlike conventional liquid cooling, direct cooling relies on phase-change heat transfer, resulting in a higher sensitivity of pressure-temperature coupling compared to liquid cooling, which increases the control accuracy requirements and practical regulation difficulty. To address this, this study constructed an experimental platform and conducted targeted investigations to analyze the effects of control parameters including compressor speed and expansion valve opening on system thermodynamic parameters and battery pack temperature distribution. With the expansion valve fixed at 3.5 turns, increasing the compressor speed from 4800 rpm to 6000 rpm maintained the maximum temperature at 45 °C, while the maximum temperature difference decreased from 7 °C to 5 °C. Among the compressor speeds, the maximum coefficient of performance (COP) of 3.46 was achieved at 4800 rpm, with a cooling capacity of 4.57 kW. Increasing the expansion valve opening further enhanced the mass flow rate. When the compressor operated at a constant speed of 4800 rpm, increasing the valve opening from 3 to 4 turns raised the cooling capacity from 4.15 kW to 5.25 kW. At 4 turns, the COP reached a maximum of 3.86. Simultaneously, the maximum battery temperature decreased from 49 °C to stabilize at 45 °C, and the maximum temperature difference decreased significantly from 11 °C to 5 °C. Furthermore, comparative analysis reveals that the system superheat and battery temperature during the charging process were higher than those during the discharging process under identical conditions, indicating greater cooling demands during charging.

Original languageEnglish
Article number123981
JournalJournal of Energy Storage
Volume179
DOIs
StatePublished - 30 Nov 2026

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy

Keywords

  • Battery temperature
  • Battery thermal management
  • Direct refrigerant cooling
  • Experimental investigation
  • System control parameters