Experimental and analytical study of a reverse-bootstrap air refrigerator for fresh air-conditioning

  • Zhefeng Wang
  • , Ze Zhang
  • , Liang Chen
  • , Shuangtao Chen
  • , Yu Hou
  • , Jinbo Li
  • , Shunkai Du
  • , Zhenkun Xu
  • , Zhuoxian Gao
  • Xi'an Jiaotong University
  • Guangdong Midea Refrigeration Equipment Co. Ltd.

Research output: Contribution to journal › Article › peer-review

1 Scopus citations

Abstract

The use of hydrofluorocarbons as refrigerants is reduced because of the increasing greenhouse effect. Air refrigeration system is environmentally friendly with air as working medium. In this study, a reverse-bootstrap air refrigeration cycle was proposed for fresh air-conditioning, which eliminated the hot heat exchanger to reduce volume and weight, and a full fresh air refrigerator was developed and tested in a psychrometric test room. Combining the characteristic curves of a motor-driven turboexpander–compressor (MTEC), a numerical model was established to analyze system off-design performance. The relative deviations between the predictions and experimental data were within 10%. The test and calculation were conducted at standard conditions (the outdoor and indoor dry and wet bulb temperature is 35/24°C and 27/19°C, respectively). The MTEC operating at design rotating speed 38 krpm could supply fresh air with a flow rate of 517.4 kg/h and temperature of 12.0°C, and a cooling capacity of 2.93 kW was obtained with a system Coefficient of performance (COP) of 0.315. The optimal COP and corresponding rotating speed will change with the variation of environmental parameters. As the outdoor temperature increases from 32 to 38°C, the optimal COP decreases by 29.6% and the corresponding rotating speed increases from 39.6 to 47.6 krpm. Moreover, when the outdoor relative humidity increases from 35% to 55% and the indoor temperature increases from 23 to 31°C, the COP decreases by 36.8% and increases by 31.9%, respectively. The advanced exergy analysis indicate the system avoidable exergy destructions account for 54.9%. Under the avoidable conditions, the efficiency of compressor, expander, and motor is 0.85, 0.85, and 0.95, respectively, the system COP can reach 0.946. The exergy destruction analysis of components indicates the importance to optimize the compressor.

Original languageEnglish
Pages (from-to)3485-3497
Number of pages13
JournalInternational Journal of Green Energy
Volume21
Issue number15
DOIs
StatePublished - 2024

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy

Keywords

  • COP
  • Fresh air condition
  • motor-driven turboexpander–compressor
  • off-design performance
  • reverse-bootstrap

Fingerprint

Dive into the research topics of 'Experimental and analytical study of a reverse-bootstrap air refrigerator for fresh air-conditioning'. Together they form a unique fingerprint.

Cite this