T1 - Experimental analysis of EMC immunity for field installed intelligent equipment, of intelligent substation
AU - Jianfei, Ji
AU - Lihui, Wang
AU - Yubo, Yuan
AU - Yifei, Yang
N1 - Publisher Copyright:
© 2014 IEEE.
PY - 2014/12/18
Y1 - 2014/12/18
N2 - With the construction of intelligent substation, it is a trend that the secondary intelligent devices are field installed. After field installation of intelligent devices, the electromagnetic environment in switch yard is much more serious than which in relay protection room. After the abnormal condition of the 100kV intelligent substation occurred, the EMC experiments are carried out and the structure of merging unit is improved. For quantitatively analyzing the strength of the disturbance signal, the electromagnetic disturbance signals are recorded when the switch operated. Besides, when another 500kV intelligent substation starts, the electromagnetic disturbance signals are also recorded. The amplitude and time-frequency characteristics of the electromagnetic disturbance signals are analyzed. Based on the results of EMC experiments and the amplitude and time-frequency characteristics of disturbance signals, this paper analyzes the applicability of EMC test standard used in China. And it is pointed out that the test standard is not enough to check the field installation secondary intelligent device. Finally, some suggestions to improving the EMC performance of field installation secondary intelligent devices are put forward.
AB - With the construction of intelligent substation, it is a trend that the secondary intelligent devices are field installed. After field installation of intelligent devices, the electromagnetic environment in switch yard is much more serious than which in relay protection room. After the abnormal condition of the 100kV intelligent substation occurred, the EMC experiments are carried out and the structure of merging unit is improved. For quantitatively analyzing the strength of the disturbance signal, the electromagnetic disturbance signals are recorded when the switch operated. Besides, when another 500kV intelligent substation starts, the electromagnetic disturbance signals are also recorded. The amplitude and time-frequency characteristics of the electromagnetic disturbance signals are analyzed. Based on the results of EMC experiments and the amplitude and time-frequency characteristics of disturbance signals, this paper analyzes the applicability of EMC test standard used in China. And it is pointed out that the test standard is not enough to check the field installation secondary intelligent device. Finally, some suggestions to improving the EMC performance of field installation secondary intelligent devices are put forward.
KW - Electromagnetic compatibility(EMC)
KW - Field installation
KW - Intelligent substation
UR - https://www.scopus.com/pages/publications/84942310821
U2 - 10.1109/CICED.2014.6991968
DO - 10.1109/CICED.2014.6991968
M3 - 会议稿件
AN - SCOPUS:84942310821
T3 - China International Conference on Electricity Distribution, CICED
SP - 1556
EP - 1564
BT - CICED 2014 - 2014 China International Conference on Electricity Distribution, Proceedings
PB - IEEE Computer Society
T2 - 2014 6th China International Conference on Electricity Distribution, CICED 2014
Y2 - 23 September 2014 through 26 September 2014
ER -