Abstract
A 2.6-MV field-distortion oil switch was developed and tested. Engineering design theories of this switch, including electrode areas, oil anode-cathode (A-K) gaps, insulator-surface electric field, and A-K gaps of the pre-gas switch, were described in detail. Structure designs of the switch were presented. Electric-field distributions of the oil A-K gap and insulator surface were analyzed and discussed. Also, switch breakdown processes were estimated. Finally, performances of this switch were tested on the "JianGuang-I" facility (2.3MV/350ns). Preliminary experiment results show that with a 250kV trigger voltage, the switch-breakdown time delay is about 132ns and its jitter (the standard deviation) is less than 4.4ns.
| Original language | English |
|---|---|
| Article number | 006121 |
| Pages (from-to) | 1978-1984 |
| Number of pages | 7 |
| Journal | IEEE Transactions on Dielectrics and Electrical Insulation |
| Volume | 24 |
| Issue number | 4 |
| DOIs | |
| State | Published - 2017 |
Keywords
- Electric field effects
- High-voltage techniques
- Jitter
- Oil insulation
- Time-delay arrays
Fingerprint
Dive into the research topics of 'Engineering Design and Primary Experiment Study of a 2.6-MV Field-Distortion Oil Switch'. Together they form a unique fingerprint.Cite this