TY - JOUR
T1 - Energy saving maximization on combined heat and power units in different scenarios
AU - Ma, Guofeng
AU - Liu, Ming
AU - Wang, Shan
AU - Li, Weidong
AU - Yan, Junjie
N1 - Publisher Copyright:
© 2023 Elsevier Ltd
PY - 2023/5/25
Y1 - 2023/5/25
N2 - Cogeneration takes several advantages of energy saving and economy. This study aims to evaluate and maximize the energy saving effect of cogeneration in different scenarios. Accordingly, optimization models on the cogeneration share coefficient, a dimensionless index describing the heat load ratio undertaken by cogeneration in district heating, are developed to maximize the energy saving with a reference case. The research results reveal that the off-design performance of cogeneration is an important factor affecting optimization. In the new scenario, the construction of new cogeneration units does not save energy when the share of renewable power in the replaced power generation is higher than the threshold value of 0.150. Moreover, the optimal cogeneration share coefficient for the electric heating boiler increases from 0.807 to 0.910, and the maximum primary energy saving increases from 4.450 × 1012 kJ·year−1 to 9.414 × 1012 kJ·year−1 when the share of heat supplied by the power-to-heat devices increases from 0 to 0.500. The optimal cogeneration share coefficient for the electric heat pump declines from 0.807 to 0.732, and the maximum primary energy saving reduces from 4.450 × 1012 kJ·year−1 to 2.632 × 1012 kJ·year−1. The obtained results show the effectiveness of the model in terms of analyzing the energy saving of cogeneration in different scenarios.
AB - Cogeneration takes several advantages of energy saving and economy. This study aims to evaluate and maximize the energy saving effect of cogeneration in different scenarios. Accordingly, optimization models on the cogeneration share coefficient, a dimensionless index describing the heat load ratio undertaken by cogeneration in district heating, are developed to maximize the energy saving with a reference case. The research results reveal that the off-design performance of cogeneration is an important factor affecting optimization. In the new scenario, the construction of new cogeneration units does not save energy when the share of renewable power in the replaced power generation is higher than the threshold value of 0.150. Moreover, the optimal cogeneration share coefficient for the electric heating boiler increases from 0.807 to 0.910, and the maximum primary energy saving increases from 4.450 × 1012 kJ·year−1 to 9.414 × 1012 kJ·year−1 when the share of heat supplied by the power-to-heat devices increases from 0 to 0.500. The optimal cogeneration share coefficient for the electric heat pump declines from 0.807 to 0.732, and the maximum primary energy saving reduces from 4.450 × 1012 kJ·year−1 to 2.632 × 1012 kJ·year−1. The obtained results show the effectiveness of the model in terms of analyzing the energy saving of cogeneration in different scenarios.
KW - Cogeneration
KW - Energy saving analysis
KW - Off-design working condition
KW - Optimal cogeneration share coefficient
KW - Separated heat and power benchmark scenario
UR - https://www.scopus.com/pages/publications/85149265783
U2 - 10.1016/j.applthermaleng.2023.120182
DO - 10.1016/j.applthermaleng.2023.120182
M3 - 文章
AN - SCOPUS:85149265783
SN - 1359-4311
VL - 226
JO - Applied Thermal Engineering
JF - Applied Thermal Engineering
M1 - 120182
ER -