TY - JOUR
T1 - Electrochemical sensor based on Cu2-xS/graphene heterostructures for sub-picomolar dopamine detection
AU - Ai, Ding
AU - Yu, Hao
AU - Han, Yuting
AU - Chang, Yuan
AU - Ma, Yanhao
AU - Wu, Chenglong
AU - Liu, Mengning
AU - Zhu, Yongsheng
AU - Li, Shengbin
AU - Dong, Chengye
AU - Cheng, Yonghong
N1 - Publisher Copyright:
© The Author(s), under exclusive licence to Springer-Verlag GmbH Austria, part of Springer Nature 2024.
PY - 2024/10
Y1 - 2024/10
N2 - Detecting dopamine (DA) in biological samples is vital to understand its crucial role in numerous physiological processes, such as motion, cognition, and reward stimulus. In this work, p-type graphene on sapphire, synthesized via chemical vapor deposition, serves as substrate for the preparation of p-type Cu2-xS films through solid-phase sulfurization. The optimized Cu2-xS/graphene heterostructure, prepared at 250 °C using a 15-nm copper film sulfurized for 2 h, exhibits superior electron transfer performance, ideal for electrochemical sensing. It is confirmed that the spontaneous charge transfer from graphene to Cu2-xS, higher Cu(II)/Cu(I) ratio (~ 0.8), and the presence of well-defined nanocrystalline structures with an average size of ~ 35 nm in Cu2-xS significantly contribute to the improved electron transfer of the heterostructure. The electrochemical sensor based on Cu2-xS/graphene heterostructure demonstrates remarkable sensitivity towards DA, with a detection limit as low as 100 fM and a dynamic range greater than 109 from 100 fM to 100 μM. Additionally, it exhibits excellent selectivity even in the presence of uric acid and ascorbic acid 100 times higher, alongside notable storage and measurement stability and repeatability. Impressively, the sensor also proves capable of detecting DA concentrations as low as 100 pM in rat serum, showcasing its potential for clinically relevant analytes and promising applications in sensitive, selective, reliable, and efficient point-of-care diagnostics. Graphical Abstract: (Figure presented.)
AB - Detecting dopamine (DA) in biological samples is vital to understand its crucial role in numerous physiological processes, such as motion, cognition, and reward stimulus. In this work, p-type graphene on sapphire, synthesized via chemical vapor deposition, serves as substrate for the preparation of p-type Cu2-xS films through solid-phase sulfurization. The optimized Cu2-xS/graphene heterostructure, prepared at 250 °C using a 15-nm copper film sulfurized for 2 h, exhibits superior electron transfer performance, ideal for electrochemical sensing. It is confirmed that the spontaneous charge transfer from graphene to Cu2-xS, higher Cu(II)/Cu(I) ratio (~ 0.8), and the presence of well-defined nanocrystalline structures with an average size of ~ 35 nm in Cu2-xS significantly contribute to the improved electron transfer of the heterostructure. The electrochemical sensor based on Cu2-xS/graphene heterostructure demonstrates remarkable sensitivity towards DA, with a detection limit as low as 100 fM and a dynamic range greater than 109 from 100 fM to 100 μM. Additionally, it exhibits excellent selectivity even in the presence of uric acid and ascorbic acid 100 times higher, alongside notable storage and measurement stability and repeatability. Impressively, the sensor also proves capable of detecting DA concentrations as low as 100 pM in rat serum, showcasing its potential for clinically relevant analytes and promising applications in sensitive, selective, reliable, and efficient point-of-care diagnostics. Graphical Abstract: (Figure presented.)
KW - Copper sulfide
KW - Differential pulse voltammetry
KW - Dopamine
KW - Electrochemical biosensor
KW - Graphene
KW - Heterostructures
KW - Sapphire substrate
UR - https://www.scopus.com/pages/publications/85203237425
U2 - 10.1007/s00604-024-06651-3
DO - 10.1007/s00604-024-06651-3
M3 - 文章
C2 - 39242473
AN - SCOPUS:85203237425
SN - 0026-3672
VL - 191
JO - Microchimica Acta
JF - Microchimica Acta
IS - 10
M1 - 578
ER -