Efficiency of removing sulfur dioxide in the air by non-thermal plasma along with the application of the magnetic field

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

The non-thermal plasma created by high voltage pulsed power supply can be used to remove sulfur dioxide in the air, but how to increase the removing efficiency is not clear. It is novel to apply the magnetic field in removing SO2 as discussed in this paper. The mechanisms of removing sulfur dioxide by non-thermal plasma along with the application of the magnetic field are analyzed, and the related factors affecting the removal efficiency, such as the magnitude of pulsed voltage, the polarity of the pulse, the layout of the discharge electrode, especially the magnetic field are experimentally investigated. It can be concluded that the purification efficiency is improved significantly by applying the magnetic field.

Original languageEnglish
Pages (from-to)3073-3077
Number of pages5
JournalPlasma Science and Technology
Volume7
Issue number5
DOIs
StatePublished - Oct 2005

Keywords

  • Magnetic field
  • Non-thermal plasma
  • Removal efficiency

Fingerprint

Dive into the research topics of 'Efficiency of removing sulfur dioxide in the air by non-thermal plasma along with the application of the magnetic field'. Together they form a unique fingerprint.